Jalandhar
We constantly involved in developing & engineering a wide range of transformers fit for the individual & industrial usage.
Dry type transformers are those that do not require a liquid like silicone or oil to cool down the electrical core and coils and are air cooled instead.
Dry type transformers, we use insulation that is F (Fiber) or H (NOMEX) class
These transformers are used in areas that are highly populated. These kinds of transformers mainly remain indoors and are especially suited for areas that are damp and contaminated. Dry type Power / Distribution Transformers Manufacturers are used in locations where safety is of utmost priority and where conventional transformers with oil / paper composite dielectric can be a liability and prone to fire hazards
For Dry type transformers, we use insulation that is F (Fiber) or H (NOMEX) class. Insulation is used either with or without enclosure as per the requirements. Our Transformers are designed in the way that they occupy less space and yet work more efficiently. The components that are used are the best in quality and are made according to the requirements and fulfilling the specifications.
We also provide outdoor dry type transformer and voltage dry type transformer. The ratings of dry-type transformers are up-to 2500kVA. The voltage class that is usually required is 3.3, 6.6, 11 kV Class, but if any other class is required then that is also provided. The applicable standards for the dry type of transformers are IS 11171 and IEC60726. There are two ways of cooling and they are natural and forced specifically called AN – Air Natural, AF- Air Forced.
The services that are provided include indoor, IP 23 and any other according to the requirements of the client. The frequency that is generally used is Dyn5 / Dyn11 and if any other frequency is required that is also provided. Dyn5 / Dyn11 or any other vector group that is required is used in the transformer.
Dyn5 / Dyn11 or any other phase that is required is used accordingly with F Class / H Class or any other IEC required. Copper or Aluminium winding material is used. The life expectancy of this kind of transformer depends upon the fact whether there has been an overload or not as winding insulation sometimes breaks down when there is a rise in the temperature due to overloading.
Rating | Upto 2500 KVA (VPI Type) | Vector Group | Dyn11 or As Per Customer Needs |
Voltage Class | Upto 33KV | Temperature Rise | 115 Degree or As Per Customer Needs |
Phase | Three Phase | Cooling | Air Natural Air Natural (ANAN) |
Frequency | 50HZ | Losses | As per Customer Needs |
Winding Material | Copper/ Aluminium (Nomex Paper) | Fittings & Accessories | As per Customer Needs |
Tapping Range | As per Customer Needs |
Plot No. 34, Bulandpur Road, Gadaipur, Back side Focal Point Jalandhar-144004 (Punjab)